1.Non Contact Infrared-ST series
Model |
ST2 |
ST3 |
ST6 |
ST8 |
Temp. Range: |
-32
to 400°C |
-32
to 400°C |
-32
to 500°C |
-32
to 540°C |
D:S (Distance to Spot size): |
8:1 |
8:1 |
8:1 |
30:1 |
Laser Sightng: |
No |
Yes |
Yes |
Yes |
Emissivity: |
pre-set to 0.95 |
pre-set to 0.95 |
adjustable |
adjustable |
Accuracy: |
±1% |
±1% |
±1% |
±1% |
Response Time: |
500 mSec |
500 mSec |
500 mSec |
500 mSec |
MAX, MIN, DIF, and AVG Temperatures: |
MAX only |
MAX only |
All |
All |
Recall Last Reading: |
No |
No |
Yes |
Yes |
HI/LO Alarm: |
No |
No |
Yes |
Yes |
Protective Hard Case: |
Yes (as option) |
Yes |
Yes |
Yes |
2.Non Contact Infrared-MT series
Specification |
|
Temperature Range |
-30 to 900°C (-25 to 1600°F) |
D:S (Distance to Spot Size) |
60:1 |
Laser Sighting |
16-point, class 2 |
Emissivity |
Adjustable |
Accuracy |
± 1% |
Response Time |
250mSec |
°C or °F |
Selectable |
Protective Hard Case |
Included |
Data output |
RS-232 or 1 mV per degree |
3.Non Contact Infrared-OS520,521,522 series
Specification(Thermocouple Input type) |
|
Model |
OS520,O521,OS522 |
Temp. range |
0 to 870¡É |
Emissivity |
Adjustable from 0.1 to 1.00 |
Indicate |
Min, Max, Average, Difference temperature |
Display |
backlit LCD |
¡É/¢µ |
selectable |
Output |
1mV/¡É |
±âŸ |
Alarm, tripod mount,trigger lock, last temp. Recall |
4.Non Contact Infrared-OS3701,37O4,3708 series
Specification(Thermocouple Input type) |
|||
Model |
OS3701 |
OS3704 |
OS3708 |
Measuring |
-50 to 1000 |
50 to 600 |
600 to 3000 |
Accuracy |
+0.8%rdg(K) |
+1.0%rdg |
+0.4¡Érdg |
Oper. mode |
Run, Peak, Valley, Average, Hold |
||
Resolution |
1° |
||
Output |
RS-232C, 1mV¡É/ |
||
Dimension |
180 x 100 x 35mm |
||
Power |
AA size battery |
||
5. Àû¿Ü¼± ¿È»ó ÃøÁ¤ÀåÄ¡(Thermal Imaging System)- TH5104
- º» ½Ã½ºÅÛÀº Á÷Á¢ ¿Âµµ ÃøÁ¤ÀÌ ºÒ°¡´ÉÇÑ
±¤¹üÀ§ÇÑ ¹èÀüÇÔ,Àü·Â°èÅë,ÀÚµ¿Â÷ ,ºôµùµîÀÇ
¿Âµµ ºÐÆ÷¸¦ ÃøÁ¤ÇϹǷΠ°úºÎÇÏ
ÃøÁ¤ ¹× ¿ ¼Õ½ÇµîÀ» ÃøÁ¤ÇÑ´Ù.
-. TH5104 Àû¿ë ºÐ¾ß
Electrical circuit breakers, panels and bus bars
Overheating of transformers
Motor and generator bearings
Energy auditing of buildings
Insulation R value determination
Roof moisture inspection
Uniformity of large area blackbody sources
-. TH5104 Ư¡ ¹× ¾Ç¼¼¼¸®
Specification |
Model : TH5104 |
Temperature range: |
Range
1: -10°C to 200°C (14°F to 392°F); |
Accuracy: |
±1.0% of range full scale span |
Temperature Dynamic Range: |
12 bits (images never saturate within range) |
Temperature Resolution (NETD): |
Range
1: 0.1°C at 30°C; |
Repeatability: |
Range
1: 0.3°C: |
Spectral response: |
3 to 5.2¥ìm |
Detector: |
Thermo-electrically cooled linear array of mercury cadmium telluride |
Total Field of View (picture size): |
21.5° Horizontal × 21.5° Vertical |
Instantaneous Field of View: |
Measurement Angle: 2.0mrad |
Number of Pixels Per Image: |
255 (H) × 223 (V) |
Focussing Distance: |
30cm (12") to infinity |
Image Update Rate: |
Fast Mode: 22 frames per second; |
Video Output: |
NTSC/PAL, RGB |
Emissivity Control: |
1.0 to 0.1 in 0.01 steps for entire image or 10 previously selected emissivity settings for up to 10 different points of image |
Automatic Functions: |
Focussing, temperature level and sensitivity, auto correction for surrounding ambient reflection |
Display Type: |
Removable 5-inch, bright active matrix, high resolution LCD screen hooded for enhanced daylight viewing. Display is removable to allow viewing difficult to reach locations. |
On-board Software Functions: |
Run/Freeze; Save image; Color, Monochromatic (positive, negative), 16, 32, 64, 128 and 256 shades of grey; Bright or rainbow colors, Up to 4 isothermal display (isotherm bands are adjustable); Up to 10 point temperature display; Up to 10 point temperature and different emissivity dosplay; Audio alarm for high or low temperatures; Date and time adjustments |
Image Storage Media: |
PCMCIA card in on-board dustproof compartment |
Image Storage Capacity: |
32, 12-bit images for 4.0MB and 150 for 20MB PCMCIA memory card |
Power Requirements: |
Rechargeable battery pack - duration 1.5
hours under normal use; 3 hours with spare battery; |
Operating Temperature: |
-10°C to 50°C (14°F to 122°F) |
Storage Temperature: |
-40°C to 70°C (-40°F to 158°F) |
Size: |
200mm (W) × 90mm (H) × 220mm (D) |
Mounting: |
¼-20 tapped hole |
Camera Weight: |
2.5kg (5.4 lbs.) |
Standard Equipment |
Optional Accessories |
1 Model TH5104 IR Camera |
Carrying Case |
2 Rechargeable Battery Packs |
Battery Vest for 5 Hour Operation |
1 Dual Battery Charger |
Offline Image Processing Software |
1 Auto Cigarette Lighter Cord |
Online Software for direct transfer of images to PC via GPIB interface |
1 Shoulder and Neck Strap |
Adapter for AC operation |
1 PCMCIA 4.0MB Memory Card |
Heavy Duty Tripod |