홈페이지로 이동  www.aeft.co.kr

                                      온도 및 습도 관련 계측기

ball04a.gif 온도/습도  Transmitter Meter & Calibrator
   
- 본 제품들은 산업, HVAC 용으로  적용분야가 다양하다.

1. Model - F/T Transmitter

Specification

Measuring Item

Temperature

Humidity

Measuring Range

-30 to+70℃

 0 to 100%RH

Repeatability

〈0.1K

〈0.5%

Accuracy

±0.5K

±2K

Time Constant

〈15sec

〈15sec

Output signal

0/4 to 20mA or 0 to 10VDC

  Sensor Type

Wall and Duct mounting

 Supply Voltage

10 to 35 VDC

Sensor protection

polyethylene Filter

Probe dimension

150 x 298(L)mm

 

2. Model - FTW65 Transmitter

Specification

Measuring Item

Temperature

Humidity

Measuring Range

-20 to +50℃

 0 to 100%RH

Repeatability

〈0.1K

〈0.5%

Accuracy

±0.5K

±2K

Time Constant

〈15sec

〈15sec

Output signal

0/4 to 20mA or 0 to 10VDC

  Sensor Type

Wall mounting

 Supply Voltage

10 to 35 VDC

Sensor protection

polyethylene Filter

Probe dimension

7.25 x 194(L)mm

 

3. Model - FTCA15 Transmitter

Specification

Measuring Item

Temperature

Humidity

Measuring Range

-30 to +100℃

 0 to 100%RH

Repeatability

〈0.1K

〈0.5%

Accuracy

±0.5K

±2.5K

Time Constant

〈15sec

〈15sec

Output signal

4 to 20mA or 0 to 10VDC

  Sensor Type

Cable Probe Type

 Supply Voltage

15 to 35 VDC

Sensor protection

Wire Filter

Probe dimension

Dia.15 x 100(L)mm

 

4. Model - DPT Transmitter

Specification

Measuring Item

Temp,Humi & calculate Dewpoint,Enthalpy,Moisture content,vapour Concentration

Measuring Range

-20 to +50℃

 0 to 100%RH

Repeatability

〈0.1K

〈0.5%

Accuracy

±0.5K

±2K

Time Constant

〈15sec

〈15sec

Output signal

0/4 to 20mA or 0 to 1/10VDC

  Sensor Type

Duct & wall Mounting type

 Supply Voltage

15 to 35 VDC

Sensor protection

Polyethylene or Wire Mash Filter

Probe dimension

Dia.15 x 250(L)mm

 

5. Model - HTO-45 Transmitter

Specification

Measuring Item

Temperature

Humidity

Measuring Range

+5 to +50℃

 0 to 90%RH

Repeatability

〈0.2K

〈0.6%

Accuracy

±1K

±3K

Time Constant

〈15sec

〈20sec

Output signal

0 to 1/10VDC

  Sensor Type

Duct & Wall Mounting Type

 Supply Voltage

5 to 24 VDC

Sensor protection

Wire Mash Filter

Probe dimension

Dia.25 x 103/250(L)mm

 

6. Model - I-1000 Transmitte

Specification

Measuring Item

Temperature

Humidity

Measuring Range

-50 to +100℃

 0 to 100%RH

Repeatability

〈0.1K

〈0.5%

Accuracy

±0.3K

±1.5K

Time Constant

〈15sec

〈15sec

Output signal

0/4 to 20mA or 0 to 1/5/10VDC

  Sensor Type

Duct,Wall & Cable Mounts Type

 Supply Voltage

15 to 35 VDC

Sensor protection

Slotted Cap(Metal)

Probe dimension

Various

 

7. Model - I-2000 Transmitter

Specification

Measuring Item

Temperature

Humidity

Measuring Range

-50 to +200℃

 0 to 100%RH

Repeatability

〈0.1K

〈0.5%

Accuracy

±0.3K

±1.5K

Time Constant

〈15sec

〈15sec

Output signal

0/4 to 20mA or 0 to 1/5/10VDC

  Sensor type

Duct & Wall Mounts Type

 Supply Voltage

15 to 35 VDC or 230/115/24 VAC

Sensor protection

Slotted Cap(Metal)

Probe dimension

Various

 

8. Model - I-3000 Transmitter

Specification

Measuring Item

Temperature

Humidity

Measuring Range

-50 to +200℃

 0 to 100%RH

Repeatability

〈0.1K

〈1.5%

Accuracy

±0.3K

±1.5K

Time Constant

〈15sec

〈15sec

Output signal

Digital RS-232C/RS-485

  Sensor type

Duct & Wall Mounts Type

 Supply Voltage

15 to 35 VDC or 230/115/24 VAC

Sensor protection

Wire filter,Sinterred Filter and Teflon Filter

Probe dimension

Various

 

8. 수분 활성도 측정장치(Water Activity)

AWC
top AWC

Portable water activity instrument.

- Fast, precise Aw measurement
- Aw range 0.01...1.00 Aw
- Hermetically sealed sample cups with integrated polyethylene filter
- ROV interface
- Compatible with A2, AM3, BT-RS1 and BT-RS8
)

AWVCtop AWVC

Aw station for accelerated results

- Fast results thanks to integrated ventilation fan
- Aw range 0.01...1.00 Aw
- Minimum hysteresis thansk Hygromer sensor
- Resistant to condensation, robust, pollutant-resistant sensor
- ROV interface
- Fan can be switched off/on manually

AWVD top AWVD

Aw station for rapid results

- Fastest results thanks to integrated ventilation fan
- Aw range 0.00...1.00 Aw
- Highest measuring accuracy, no hysteresis
- Hygrolyt sensor for high-humidity use with ROV interface
 

WA-14top WA-14 with Hygrolyt sensor

The material to be measured is enclosed, together with the sensor, in a small air tight space,. In this way a humidity and temperature equilibrium is created between material and sensor.

- Practical fast-action closure
- Compatible with BT-RS1 and DT2
- Hygrolyt interface

WA-40top WA-40 with Hygrolyt sensor

Measuring sation as for WA-14, but for larger product qantities, incorporating the same closure.

- Compatible with BT-RS1 and DT2
- Hygrolyt interface
 
 

WA-14THtop WA-14TH with Hygrolyt sensor

These probes are temperatur controlled measuring sations for very accuarte measurements of the equilibrium humidity on small product samples. They are suitable for measuring water activity under difficult measuring conditions.

- Compatible with BT-RS1 and DT2
- Hygrolyt interface


WA-40TH
top WA-40TH with Hygrolyt sensor

Measuring sation as for WA-14TH, but for largerproduct quantities.

- Compatible with BT-RS1 and DT2
- Hygrolyt interface

 

 

  house14b.gifHome     blue1_3.gif       blue1_1.gif

AEFT                      엡트텍                
                                                         e-mail :aefttech@kornet.net
                                                         
homepage : www.aeft.co.kr        



                                        Copyrightⓒ 2000 by  엡트텍. All right reserved.