ȨÆäÀÌÁö·Î À̵¿ www.aeft.co.kr
¿Âµµ ¹× ½Àµµ °ü·Ã °èÃø±â
¿Âµµ/½Àµµ
Transmitter Meter & Calibrator
- º»
Á¦Ç°µéÀº »ê¾÷, HVAC ¿ëÀ¸·Î Àû¿ëºÐ¾ß°¡ ´Ù¾çÇÏ´Ù.
1. Model - F/T Transmitter
Specification |
||
Measuring Item |
Temperature |
Humidity |
Measuring Range |
-30 to+70¡É |
0 to 100%RH |
Repeatability |
¡´0.1K |
¡´0.5% |
Accuracy |
±0.5K |
±2K |
Time Constant |
¡´15sec |
¡´15sec |
Output signal |
0/4 to 20mA or 0 to 10VDC |
|
Sensor Type |
Wall and Duct mounting |
|
Supply Voltage |
10 to 35 VDC |
|
Sensor protection |
polyethylene Filter |
|
Probe dimension |
150 x 298(L)mm |
|
2. Model - FTW65 Transmitter
Specification |
||
Measuring Item |
Temperature |
Humidity |
Measuring Range |
-20 to +50¡É |
0 to 100%RH |
Repeatability |
¡´0.1K |
¡´0.5% |
Accuracy |
±0.5K |
±2K |
Time Constant |
¡´15sec |
¡´15sec |
Output signal |
0/4 to 20mA or 0 to 10VDC |
|
Sensor Type |
Wall mounting |
|
Supply Voltage |
10 to 35 VDC |
|
Sensor protection |
polyethylene Filter |
|
Probe dimension |
7.25 x 194(L)mm |
|
3. Model - FTCA15 Transmitter
Specification |
||
Measuring Item |
Temperature |
Humidity |
Measuring Range |
-30 to +100¡É |
0 to 100%RH |
Repeatability |
¡´0.1K |
¡´0.5% |
Accuracy |
±0.5K |
±2.5K |
Time Constant |
¡´15sec |
¡´15sec |
Output signal |
4 to 20mA or 0 to 10VDC |
|
Sensor Type |
Cable Probe Type |
|
Supply Voltage |
15 to 35 VDC |
|
Sensor protection |
Wire Filter |
|
Probe dimension |
Dia.15 x 100(L)mm |
|
4. Model - DPT Transmitter
Specification |
||
Measuring Item |
Temp,Humi & calculate Dewpoint,Enthalpy,Moisture content,vapour Concentration |
|
Measuring Range |
-20 to +50¡É |
0 to 100%RH |
Repeatability |
¡´0.1K |
¡´0.5% |
Accuracy |
±0.5K |
±2K |
Time Constant |
¡´15sec |
¡´15sec |
Output signal |
0/4 to 20mA or 0 to 1/10VDC |
|
Sensor Type |
Duct & wall Mounting type |
|
Supply Voltage |
15 to 35 VDC |
|
Sensor protection |
Polyethylene or Wire Mash Filter |
|
Probe dimension |
Dia.15 x 250(L)mm |
|
5. Model - HTO-45 Transmitter
Specification |
||
Measuring Item |
Temperature |
Humidity |
Measuring Range |
+5 to +50¡É |
0 to 90%RH |
Repeatability |
¡´0.2K |
¡´0.6% |
Accuracy |
±1K |
±3K |
Time Constant |
¡´15sec |
¡´20sec |
Output signal |
0 to 1/10VDC |
|
Sensor Type |
Duct & Wall Mounting Type |
|
Supply Voltage |
5 to 24 VDC |
|
Sensor protection |
Wire Mash Filter |
|
Probe dimension |
Dia.25 x 103/250(L)mm |
|
6. Model - I-1000 Transmitte
Specification |
||
Measuring Item |
Temperature |
Humidity |
Measuring Range |
-50 to +100¡É |
0 to 100%RH |
Repeatability |
¡´0.1K |
¡´0.5% |
Accuracy |
±0.3K |
±1.5K |
Time Constant |
¡´15sec |
¡´15sec |
Output signal |
0/4 to 20mA or 0 to 1/5/10VDC |
|
Sensor Type |
Duct,Wall & Cable Mounts Type |
|
Supply Voltage |
15 to 35 VDC |
|
Sensor protection |
Slotted Cap(Metal) |
|
Probe dimension |
Various |
|
7. Model - I-2000 Transmitter
Specification |
||
Measuring Item |
Temperature |
Humidity |
Measuring Range |
-50 to +200¡É |
0 to 100%RH |
Repeatability |
¡´0.1K |
¡´0.5% |
Accuracy |
±0.3K |
±1.5K |
Time Constant |
¡´15sec |
¡´15sec |
Output signal |
0/4 to 20mA or 0 to 1/5/10VDC |
|
Sensor type |
Duct & Wall Mounts Type |
|
Supply Voltage |
15 to 35 VDC or 230/115/24 VAC |
|
Sensor protection |
Slotted Cap(Metal) |
|
Probe dimension |
Various |
|
8. Model - I-3000 Transmitter
Specification |
||
Measuring Item |
Temperature |
Humidity |
Measuring Range |
-50 to +200¡É |
0 to 100%RH |
Repeatability |
¡´0.1K |
¡´1.5% |
Accuracy |
±0.3K |
±1.5K |
Time Constant |
¡´15sec |
¡´15sec |
Output signal |
Digital RS-232C/RS-485 |
|
Sensor type |
Duct & Wall Mounts Type |
|
Supply Voltage |
15 to 35 VDC or 230/115/24 VAC |
|
Sensor protection |
Wire filter,Sinterred Filter and Teflon Filter |
|
Probe dimension |
Various |
|
8. ¼öºÐ Ȱ¼ºµµ ÃøÁ¤ÀåÄ¡(Water Activity)
AWC
Portable water activity instrument.
- Fast, precise Aw measurement
- Aw range 0.01...1.00 Aw
- Hermetically sealed sample cups with integrated polyethylene filter
- ROV interface
- Compatible with A2, AM3, BT-RS1 and BT-RS8)

AWVC
Aw station for accelerated results
- Fast results thanks to integrated ventilation fan
- Aw range 0.01...1.00 Aw
- Minimum hysteresis thansk Hygromer sensor
- Resistant to condensation, robust, pollutant-resistant sensor
- ROV interface
- Fan can be switched off/on manually

AWVD
Aw station for rapid results
- Fastest results thanks to integrated ventilation fan
- Aw range 0.00...1.00 Aw
- Highest measuring accuracy, no hysteresis
- Hygrolyt sensor for high-humidity use with ROV interface

WA-14
with Hygrolyt sensor
The material to be measured
is enclosed, together with the sensor, in a small air tight space,. In this
way a humidity and temperature equilibrium is created between material and sensor.
- Practical fast-action closure
- Compatible with BT-RS1 and DT2
- Hygrolyt interface

WA-40
with Hygrolyt sensor
Measuring sation as for WA-14,
but for larger product qantities, incorporating the same closure.
- Compatible with BT-RS1 and DT2
- Hygrolyt interface

WA-14TH
with Hygrolyt sensor
These probes are temperatur controlled measuring sations for very accuarte measurements
of the equilibrium humidity on small product samples. They are suitable for
measuring water activity under difficult measuring conditions.
- Compatible with BT-RS1 and DT2
- Hygrolyt interface

WA-40TH
with Hygrolyt sensor
Measuring sation as for WA-14TH,
but for largerproduct quantities.
- Compatible with BT-RS1 and DT2
- Hygrolyt interface
AEFT
¿¦Æ®ÅØ
e-mail
:aefttech@kornet.net
homepage : www.aeft.co.kr